PT. TIRTA JAYA PRIMAKARSA

www.tirtajayaprima.co.id

email
Email
info@tirtajayaprima.com
phone
Call us on
+6221-58304610
PRODUCT
PHOENIX CONTACT INTERFACE

Convering all aspects of industrial control, the INTERFACE provides all the components required for the signal conditioning of digital, analog, serial, and power signals, such as signal converters, switching devices and power supply units, Relay Module

Product Preview

  • new_releases Redundancy module, with protective coating – QUINT-ORING/24DC/2X20/1X40 – 2320186

    Active QUINT redundancy module for DIN rail mounting with ACB (auto current balancing) technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 20 A or 1 x 40 A, including mounted UTA 107/30 universal DIN rail adapter.

     

  • new_releases Redundancy module, with protective coating – QUINT-ORING/24DC/2X10/1X20 – 2320173

    Active QUINT redundancy module for DIN rail mounting with ACB (auto current balancing) technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted UTA 107/30 universal DIN rail adapter

     

  • new_releases Redundancy module – QUINT-DIODE/40 – 2938963

    Redundancy module QUINT-DIODE/40.

  • new_releases Power supply unit – TRIO-PS/1AC/24DC/10 – 2866323

    Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/10 A. Product Description

    TRIO POWER power supplies with standard functionality
    TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.
    The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.

  • new_releases Power supply unit – QUINT-PS/1AC/24DC/40 – 2866789

    Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/40 A.

  • new_releases Power supply unit – QUINT-PS/1AC/24DC/20 – 2866776

     

    Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/20 A.

  • new_releases Power supply unit – QUINT-PS/1AC/24DC/10 – 2866763

    Primary-switched QUINT POWER supply for DIN rail mounting with SFB (selective fuse breaking) technology, input: 1-phase, output: 24 V DC/10 A

     

  • new_releases Power supply unit – QUINT-PS/1AC/24DC/ 3.5 – 2866747

    Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/3.5 A.

  • new_releases Power supply unit – MINI-PS-100-240AC/10-15DC/2 – 2938756

    Primary-switched MINI POWER power supply for DIN rail mounting, input: 1-phase, output: 10 V DC … 15 V DC/2 A.

  • new_releases Power supply unit – MINI-PS-100-240AC/24DC/1 – 2938840

    DIN rail power supply unit 24 V DC/1 A, primary-switched mode, slim design.

  • new_releases Industrial Ethernet Switch – FL SWITCH SFN 8GT – 2891673

    Ethernet switch, eight TP-RJ45 ports with 10/100/1000 Mbps on all ports, automatic detection of data transmission speed of 10/100/1000 Mbps (RJ45), autocrossing function, with signaling contact and QoS, extended temperature range.

  • new_releases Industrial Ethernet Switch – FL SWITCH SF 8TX – 2832771

    Ethernet Switch, 8 TP RJ45 ports, automatic detection of data transmission speed of 10 or 100 Mbps (RJ45), autocrossing function

     

  • new_releases D-SUB bus connector – SUBCON-PLUS-PROFIB – 2744348

    D-SUB plug, 9-pos., pin, axial version with two cable entries, below 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; spring-cage connection terminal blocks

  • new_releases D-SUB bus connector – SUBCON 9/F-SH – 2761499

    D-SUB plug, 9-pos. female connector, one cable entry < 35°, universal type for all systems, pin assignment: 1, 2, 3, 4, 5, 6, 7, 8, 9 to screw connection terminal block

  • new_releases Solid-state relay module – PLC-OSC-230UC/ 48DC/100 – 2966757

    version PLC-BSC- 24DC/21

    PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 230 V AC/220 V DC, output: 3 – 48 V DC/100 mA.

  • new_releases Solid-state relay module – PLC-OSC- 24DC/ 48DC/100 – 2966728

    PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 3 – 48 V DC/100 mA

  • new_releases Solid-state relay module – PLC-OSC- 24DC/ 24DC/ 2 – 2966634

    version PLC-BSC- 24DC/21

    PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 3 – 33 V DC/3 A

  • new_releases Relay Module – PLC-RSP-230UC/21-21 – 2912552

    PLC relay, consisting of base terminal block PLC-BSP…/21 with spring-cage connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 230 V AC / 220 V DC.

  • new_releases Relay Module – PLC-RSC- 24DC/21-21 – 2967060

    PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 2 PDT, input voltage 24 V DC

  • new_releases Relay Module – PLC-RSC-120UC/21 – 2966197

    version PLC-RSC-24DC/21

    PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 120 V AC / 110 V DC.

  • new_releases Relay Module – PLC-RSC- 24DC/21 – 2966171

    PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 24 V DC

     

     

  • new_releases Relay socket – PLC-BSC- 24DC/21 – 2966016

    6.2 mm PLC basic terminal block with screw connection, without relays or solid-state relay, for mounting on DIN rail NS 35/7,5, 1 PDT, input voltage 24 V DC .

  • new_releases Single relay – REL-MR- 60DC/21 – 2961118

    version REL-MR- 24DC/21
    Plug-in miniature power relay, with power contact, 1 PDT, input voltage 60 V DC

  • new_releases Single relay – REL-MR- 24DC/21 – 2961105

    Plug-in miniature power relay, with power contact, 1 PDT, input voltage 24 V DC  .

  • new_releases Current transducers – MACX MCR-SL-CAC- 5-I-UP – 2810625

    Current measuring transducer for 1 A and 5 A AC, the output signal 0…20 mA or 4…20 mA, can be configured using a DIP switch with an operating mode indication through an LED.

    Product Description

    The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0…20 mA or 4…20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output current.
    The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
    The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.

  • new_releases Current transducers – MACX MCR-SL-CAC- 5-I – 2810612

    MACX MCR-SL-CAC-5-I-UP

    Current measuring transducer for 1 A and 5 A AC, the output signal 0…20 mA or 4…20 mA, can be configured using a DIP switch with an operating mode indication through an LED. Product Description

    The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0…20 mA or 4…20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output current.
    The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
    The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.

     

     

  • new_releases Loop-powered isolators – MCR-1CLP-I-I-00 – 2814016

    MCR passive isolator, for the electrical isolation of current signals without auxiliary power, 1-channel, input signal: 0(4)…20 mA, output signal: 0(4)…20 mA

  • new_releases Current transducers – MCR-SL-S-100-I-LP – 2813486

    MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0…100 A, loop-powered output with 4…20 mA

  • new_releases Current transducers – MCR-S-1-5-UI-DCI-NC – 2814715

    MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0…0.2 to 0…11 A, unconfigured.

  • new_releases Frequency transducer – MCR-F-UI-DC – 2814605

    MCR frequency measuring transducer, programmable, for converting frequencies into analog signals, with 3-way isolation and configurable output

  • new_releases Signal conditioner – MCR-C-U-U-DC – 2814469

    MCR 3-way isolating amplifier, for electrical isolation of analog signals, input signal: 0 … 10 V/(+/-)10 V, output signal: 0 … 10 V/(+/-)10 V.

  • new_releases Loop-powered isolators – MCR-2CLP-I-I-00 – 2814029

    MCR passive isolator, for the electrical isolation of current signals without auxiliary power, 2-channel, input signal: 0(4)…20 mA, output signal: 0(4)…20 mA

  • new_releases Signal conditioner – MCR-FL-C-UI-2UI-DCI-NC – 2814867

    MCR signal multiplier, for doubling and electrical isolation of analog signals, unconfigured.

  • new_releases Repeater power supply – MINI MCR-SL-RPSS-I-I – 2864079

    MCR repeater power supply with HART transmission, input signal 4…20 mA, output signal 4…20 mA, with screw connection. Product Description

    The 6.2 mm wide MINI MCR-SL-RPSS-I-I… repeater power supply supplies the transmitter in the field in case of simultaneous galvanic 3-way separation between input, output and supply.
    HART data protocols can be transmitted bidirectionally. The module can be used in both isolator and repeater power supply operation.
    On the input and output side, the analog standard signals 0…20 mA or 4…20 mA are available, electrically isolated.
    Voltage (20.4 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.

  • new_releases Resistance thermometer measuring transducer – MINI MCR-SL-PT100-UI-NC – 2864273

    MCR temperature transducer for Pt 100 temperature sensors, configured via DIP switch, with screw connection, not pre-configured.   Product Description

    The 6.2 mm wide MINI MCR-SL-PT100-UI… is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.
    On the output side, the analog standard signals 0…20 mA, 4…20 mA, 0…10 V, 0…5 V, 1…5 V, 10…0 V, 20…0 mA or 20…4 mA are available, electrically isolated.
    The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:
    – Connection method
    – Temperature range to be measured
    – Output signal as well
    – Fault evaluation type
    Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.

  • new_releases Temperature measuring transducer – MINI MCR-SL-PT100-LP-NC – 2810308

    Configurable loop-powered temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with screw connection, not pre-configured.

  • new_releases Signal conditioner – MINI MCR-SL-UI-UI-NC – 2864150

    3-way isolating amplifier for the electrical isolation of analog signals, I/O can be configured via DIP switches, with screw connection, standard configuration.

  • new_releases Active termination resistor

    To complete your PROFIBUS network, you can use a PSI-Terminator, which measures only 22 millimeters, optionally with a D-SUB or COMBICON plug. In addition, the device functions as a service interface for active and passive programming devices. Diagnostic LEDs notify you of bus and diagnostics activity as well as the power supply.

  • new_releases Configurable power supplies for superior system availability

    The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions. Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.

  • new_releases The smart software for the Axioline I/O system: Startup+

    Startup+ can be used to display and operate your Axioline station during startup – without having to connect the station to a higher-level network. In addition, Startup+ offers many useful functions for all aspects of the Axioline I/O system:

    1. Reading and writing input and output signals
    2. Comprehensive diagnostics during operation
    3. User-friendly connection of software to an Axioline station via the fieldbus or service interface
    4. Support in connecting to the Axioline station by means of a wizard
    5. Software is open for connection to TCI interfaces (for DTM integration in engineering systems)
  • new_releases Bluetooth adapter for wireless communication

    Conveniently exchange data between Interface products and mobile terminal devices using the new Bluetooth adapter. The wireless connection enables more convenient control and regulation processes in industrial applications.

  • new_releases PLC actuator series

    PLC actuator series: Interface between the PLC and actuators
    When used as an interface between the PLC and actuators, only one N/O contact function is normally required. Ideal for 2-wire output field devices, including small motors, contactors or solenoid valves.  

    In such cases: 

    • The PLC … ACT output relay is used
    • All actuator connections – including the load return line – are connected directly to the relay base
    • This eliminates the need for additional output terminal blocks – saving time, space and money

     

  • new_releases PLC universal series

    PLC universal series can be used as an input or output interface
    The universal series can be used as an input or output interface.

    • The PLC universal series consists of a basic terminal block with a plug-in miniature relay (PDT contact) or a plug-in solid-state relay
    • Sensors/actuators are connected via modular terminal blocks
  • new_releases Digital extension module for Interface system gateways

    For more complex applications with Interface system devices (IFS), the new extension module offers digital inputs and outputs for processing additional signals from the field. Quickly and easily connect the module to an IFS gateway as a slave via the DIN rail connector.

  • new_releases Signal duplicator – MINI MCR-SL-UI-2I-NC – 2864176

    4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration. Product Description

    The 6.2 mm wide configurable 4-way isolating amplifier MINI MCR-SL-UI-2I-… is used for electrical isolation, conversion, amplification and filtering of standard signals.
    On the input side, the analog standard signals 0…20 mA, 4…20 mA, 0…10 V or 1…5V can be selected, on the output side there are two current outputs that can be set independently of one another with a 0…20 mA-, or 4…20mA signal, electrically isolated (4-way isolation).
    The DIP switches, which can be accessed on the side of the housing, can be used to configure the input and output signal ranges.
    Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.

  • new_releases System cabling for DCS and PLC

    Fast, reliable connection
    Eliminate long installation times and costly wiring errors with pluggable, high-speed system cabling.

  • new_releases System cabling for signal conditioners

    Signal connection – quick and error-free
    Connect large numbers of signals from the field to your automation system – very easily with system cabling via Plug and Play. Termination Carriers from Phoenix Contact offer a consistent system solution from the interface level to the process control level. Select the appropriate functions for signal conditioning from a wide range of standard DIN rail devices and equip your Termination Carriers accordingly.

  • new_releases Hybrid motor starters

    Clever motor switching
    Switch and reverse motors quickly and reliably with compact hybrid motor starters

  • new_releases Programmable logic relay system

    Extremely compact control and switching
    Combine the relays and analog modules with logic functions and intuitive software.

  • new_releases COM server

    Optimum connection
    Make your devices network capable. COM servers connect serial interfaces to the Ethernet.

  • new_releases HMIs and industrial PCs

    Keep a closer eye on automation
    With our comprehensive range of hardware and software for all aspects of operation and monitoring.

  • new_releases Copper to copper transmission

    Combine interfaces
    Combine different interfaces easily and network your application in a secure, reliable and structured way.

  • new_releases Highly-compact relay modules

    Slim relays; high-performance

    The terminal block relay series suitable for universal use, offers a wide range of solutions for all applications. The PLC-INTERFACE relay system is the high-performance interface between the controller and system I/O devices. PLC relay series provides you with a complete range of universal plug-in electromechanical and solid-state relay modules for interposing or isolation applications.  In additional to the universal relays several specialty relays are available including: actuators, sensors, leakage current filters, high current, CID2, ATEX and many others.

    These relays are compatible with a wide range of accessories, including system cable adapters, feed terminals and plug-in bridges.  Incorporating these accessories into your design can help create completely pluggable connections between the controller and the relays.

  • new_releases Industrial communication technology

    Reliable communication

    Increase the availability of your application – with high-performance data interfaces. Using industrial communication technology from Phoenix Contact, you can increase the degree of automation of your systems. We offer a comprehensive range of high-performance interface devices that meet the high demands of modern applications.

  • new_releases Converters and isolators

    Adapt interfaces

    Whether you want to convert interfaces to other standards or increase immunity to interference, we have the right solution for your requirements.  Converters from Phoenix Contact enable you to convert different serial interfaces to other standards with a transparent protocol. Thanks to electrical isolators, you can avoid dangerous compensating currents and protect termination devices against transient coupling effectively.

  • new_releases Bluetooth Serial

    Bluetooth technology for serial data

    Use the Bluetooth interface converter as a simple solution for replacing serial cabling. The Bluetooth converter can be used to convert serial interfaces such as USB or RS-232/RS-422/RS-485 to the license-free Bluetooth wireless standard. You can also use the converter as an inexpensive alternative to slip rings, drag chains or fieldbus cables. Your advantage: use the Bluetooth converter as an access point and call control data via notebooks or PDAs.

  • new_releases AS-Interface

    Easy automation

    Reduce your workload: mounting and handling made easy. Want to save time, use fewer cables, and network your system quickly and easily in the field? The components for AS-Interface networks are the intelligent solution.

    Efficient automation

    Reduce your workload: our AS-Interface components can be easily mounted and feature user-friendly handling.  Get a quick, easy and error-free way of wiring.  AS-Interface does not require any special prior knowledge when it comes to installation, which is one of the reasons why it is setting new standards in automation. In addition you can cut your installation, configuration and maintenance costs for machines and systems. Phoenix Contact offers a complete product portfolio for AS-Interface.

  • new_releases PLC universal series

    PLC universal series can be used as an input or output interface

    The universal series can be used as an input or output interface.

    • The PLC universal series consists of a basic terminal block with a plug-in miniature relay (PDT contact) or a plug-in solid-state relay
    • Sensors/actuators are connected via modular terminal blocks
  • new_releases Digital extension module for Interface system gateways

    For more complex applications with Interface system devices (IFS), the new extension module offers digital inputs and outputs for processing additional signals from the field. Quickly and easily connect the module to an IFS gateway as a slave via the DIN rail connector.

  • new_releases Produk Interface

    Lorem ipsum dolor sit amet, consectetur adipisicing elit. Voluptatem, cupiditate sequi velit. Obcaecati excepturi quibusdam deleniti commodi eveniet in hic sed tenetur nemo laudantium labore omnis amet, dolorum, impedit, eos!