www.tirtajayaprima.co.id
|
|
info@tirtajayaprima.com |
phone | Call us on |
+6221-58304610 |
Convering all aspects of industrial control, the INTERFACE provides all the components required for the signal conditioning of digital, analog, serial, and power signals, such as signal converters, switching devices and power supply units, Relay Module
Product Preview
Active QUINT redundancy module for DIN rail mounting with ACB (auto current balancing) technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 20 A or 1 x 40 A, including mounted UTA 107/30 universal DIN rail adapter.
Active QUINT redundancy module for DIN rail mounting with ACB (auto current balancing) technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted UTA 107/30 universal DIN rail adapter
Redundancy module QUINT-DIODE/40.
Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/10 A. Product Description
TRIO POWER power supplies with standard functionality
TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.
The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/40 A.
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/20 A.
Primary-switched QUINT POWER supply for DIN rail mounting with SFB (selective fuse breaking) technology, input: 1-phase, output: 24 V DC/10 A
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/3.5 A.
Primary-switched MINI POWER power supply for DIN rail mounting, input: 1-phase, output: 10 V DC … 15 V DC/2 A.
DIN rail power supply unit 24 V DC/1 A, primary-switched mode, slim design.
Ethernet switch, eight TP-RJ45 ports with 10/100/1000 Mbps on all ports, automatic detection of data transmission speed of 10/100/1000 Mbps (RJ45), autocrossing function, with signaling contact and QoS, extended temperature range.
Ethernet Switch, 8 TP RJ45 ports, automatic detection of data transmission speed of 10 or 100 Mbps (RJ45), autocrossing function
D-SUB plug, 9-pos., pin, axial version with two cable entries, below 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; spring-cage connection terminal blocks
D-SUB plug, 9-pos. female connector, one cable entry < 35°, universal type for all systems, pin assignment: 1, 2, 3, 4, 5, 6, 7, 8, 9 to screw connection terminal block
version PLC-BSC- 24DC/21
PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 230 V AC/220 V DC, output: 3 – 48 V DC/100 mA.
PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 3 – 48 V DC/100 mA
version PLC-BSC- 24DC/21
PLC-INTERFACE, consisting of PLC-BSC…/21 basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 3 – 33 V DC/3 A
PLC relay, consisting of base terminal block PLC-BSP…/21 with spring-cage connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 230 V AC / 220 V DC.
PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 2 PDT, input voltage 24 V DC
version PLC-RSC-24DC/21
PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 120 V AC / 110 V DC.
PLC relay, consisting of base terminal block PLC-BSC…/21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 1 PDT, input voltage 24 V DC
6.2 mm PLC basic terminal block with screw connection, without relays or solid-state relay, for mounting on DIN rail NS 35/7,5, 1 PDT, input voltage 24 V DC .
version REL-MR- 24DC/21
Plug-in miniature power relay, with power contact, 1 PDT, input voltage 60 V DC
Plug-in miniature power relay, with power contact, 1 PDT, input voltage 24 V DC .
Current measuring transducer for 1 A and 5 A AC, the output signal 0…20 mA or 4…20 mA, can be configured using a DIP switch with an operating mode indication through an LED.
Product Description
The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0…20 mA or 4…20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output current.
The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.
MACX MCR-SL-CAC-5-I-UP
Current measuring transducer for 1 A and 5 A AC, the output signal 0…20 mA or 4…20 mA, can be configured using a DIP switch with an operating mode indication through an LED. Product Description
The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0…20 mA or 4…20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output current.
The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.
MCR passive isolator, for the electrical isolation of current signals without auxiliary power, 1-channel, input signal: 0(4)…20 mA, output signal: 0(4)…20 mA
MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0…100 A, loop-powered output with 4…20 mA
MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0…0.2 to 0…11 A, unconfigured.
MCR frequency measuring transducer, programmable, for converting frequencies into analog signals, with 3-way isolation and configurable output
MCR 3-way isolating amplifier, for electrical isolation of analog signals, input signal: 0 … 10 V/(+/-)10 V, output signal: 0 … 10 V/(+/-)10 V.
MCR passive isolator, for the electrical isolation of current signals without auxiliary power, 2-channel, input signal: 0(4)…20 mA, output signal: 0(4)…20 mA
MCR signal multiplier, for doubling and electrical isolation of analog signals, unconfigured.
MCR repeater power supply with HART transmission, input signal 4…20 mA, output signal 4…20 mA, with screw connection. Product Description
The 6.2 mm wide MINI MCR-SL-RPSS-I-I… repeater power supply supplies the transmitter in the field in case of simultaneous galvanic 3-way separation between input, output and supply.
HART data protocols can be transmitted bidirectionally. The module can be used in both isolator and repeater power supply operation.
On the input and output side, the analog standard signals 0…20 mA or 4…20 mA are available, electrically isolated.
Voltage (20.4 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
MCR temperature transducer for Pt 100 temperature sensors, configured via DIP switch, with screw connection, not pre-configured. Product Description
The 6.2 mm wide MINI MCR-SL-PT100-UI… is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of Pt 100 resistance thermometers according to IEC 60751 in 2, 3 and 4-wire connection methods.
On the output side, the analog standard signals 0…20 mA, 4…20 mA, 0…10 V, 0…5 V, 1…5 V, 10…0 V, 20…0 mA or 20…4 mA are available, electrically isolated.
The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:
– Connection method
– Temperature range to be measured
– Output signal as well
– Fault evaluation type
Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
Configurable loop-powered temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with screw connection, not pre-configured.
3-way isolating amplifier for the electrical isolation of analog signals, I/O can be configured via DIP switches, with screw connection, standard configuration.
To complete your PROFIBUS network, you can use a PSI-Terminator, which measures only 22 millimeters, optionally with a D-SUB or COMBICON plug. In addition, the device functions as a service interface for active and passive programming devices. Diagnostic LEDs notify you of bus and diagnostics activity as well as the power supply.
The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions. Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.
Startup+ can be used to display and operate your Axioline station during startup – without having to connect the station to a higher-level network. In addition, Startup+ offers many useful functions for all aspects of the Axioline I/O system:
Conveniently exchange data between Interface products and mobile terminal devices using the new Bluetooth adapter. The wireless connection enables more convenient control and regulation processes in industrial applications.
PLC actuator series: Interface between the PLC and actuators
When used as an interface between the PLC and actuators, only one N/O contact function is normally required. Ideal for 2-wire output field devices, including small motors, contactors or solenoid valves.
In such cases:
PLC universal series can be used as an input or output interface
The universal series can be used as an input or output interface.
For more complex applications with Interface system devices (IFS), the new extension module offers digital inputs and outputs for processing additional signals from the field. Quickly and easily connect the module to an IFS gateway as a slave via the DIN rail connector.
4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration. Product Description
The 6.2 mm wide configurable 4-way isolating amplifier MINI MCR-SL-UI-2I-… is used for electrical isolation, conversion, amplification and filtering of standard signals.
On the input side, the analog standard signals 0…20 mA, 4…20 mA, 0…10 V or 1…5V can be selected, on the output side there are two current outputs that can be set independently of one another with a 0…20 mA-, or 4…20mA signal, electrically isolated (4-way isolation).
The DIP switches, which can be accessed on the side of the housing, can be used to configure the input and output signal ranges.
Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
Fast, reliable connection
Eliminate long installation times and costly wiring errors with pluggable, high-speed system cabling.
Signal connection – quick and error-free
Connect large numbers of signals from the field to your automation system – very easily with system cabling via Plug and Play. Termination Carriers from Phoenix Contact offer a consistent system solution from the interface level to the process control level. Select the appropriate functions for signal conditioning from a wide range of standard DIN rail devices and equip your Termination Carriers accordingly.
Clever motor switching
Switch and reverse motors quickly and reliably with compact hybrid motor starters
Extremely compact control and switching
Combine the relays and analog modules with logic functions and intuitive software.
Optimum connection
Make your devices network capable. COM servers connect serial interfaces to the Ethernet.
Keep a closer eye on automation
With our comprehensive range of hardware and software for all aspects of operation and monitoring.
Combine interfaces
Combine different interfaces easily and network your application in a secure, reliable and structured way.
Slim relays; high-performance
The terminal block relay series suitable for universal use, offers a wide range of solutions for all applications. The PLC-INTERFACE relay system is the high-performance interface between the controller and system I/O devices. PLC relay series provides you with a complete range of universal plug-in electromechanical and solid-state relay modules for interposing or isolation applications. In additional to the universal relays several specialty relays are available including: actuators, sensors, leakage current filters, high current, CID2, ATEX and many others.
These relays are compatible with a wide range of accessories, including system cable adapters, feed terminals and plug-in bridges. Incorporating these accessories into your design can help create completely pluggable connections between the controller and the relays.
Reliable communication
Increase the availability of your application – with high-performance data interfaces. Using industrial communication technology from Phoenix Contact, you can increase the degree of automation of your systems. We offer a comprehensive range of high-performance interface devices that meet the high demands of modern applications.
Adapt interfaces
Whether you want to convert interfaces to other standards or increase immunity to interference, we have the right solution for your requirements. Converters from Phoenix Contact enable you to convert different serial interfaces to other standards with a transparent protocol. Thanks to electrical isolators, you can avoid dangerous compensating currents and protect termination devices against transient coupling effectively.
Bluetooth technology for serial data
Use the Bluetooth interface converter as a simple solution for replacing serial cabling. The Bluetooth converter can be used to convert serial interfaces such as USB or RS-232/RS-422/RS-485 to the license-free Bluetooth wireless standard. You can also use the converter as an inexpensive alternative to slip rings, drag chains or fieldbus cables. Your advantage: use the Bluetooth converter as an access point and call control data via notebooks or PDAs.
Easy automation
Reduce your workload: mounting and handling made easy. Want to save time, use fewer cables, and network your system quickly and easily in the field? The components for AS-Interface networks are the intelligent solution.
Efficient automation
Reduce your workload: our AS-Interface components can be easily mounted and feature user-friendly handling. Get a quick, easy and error-free way of wiring. AS-Interface does not require any special prior knowledge when it comes to installation, which is one of the reasons why it is setting new standards in automation. In addition you can cut your installation, configuration and maintenance costs for machines and systems. Phoenix Contact offers a complete product portfolio for AS-Interface.
PLC universal series can be used as an input or output interface
The universal series can be used as an input or output interface.
For more complex applications with Interface system devices (IFS), the new extension module offers digital inputs and outputs for processing additional signals from the field. Quickly and easily connect the module to an IFS gateway as a slave via the DIN rail connector.
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Voluptatem, cupiditate sequi velit. Obcaecati excepturi quibusdam deleniti commodi eveniet in hic sed tenetur nemo laudantium labore omnis amet, dolorum, impedit, eos!